PVC Elbow 45 Degree Pressure Fittings Adhesive Water Pipe Fitting ID 20mm~ 125mm

Keine Bewertungen

Preis:
Sonderpreis$1.82 USD
Lagerbestand:
Verfügbar (500 Stück), versandbereit

Payment & Security

Ach Direct Debit Amazon American Express Apple Pay Bancontact BLIK Diners Club Discover EPS Google Pay iDEAL Wero JCB Maestro Mastercard Multibanco MobilePay PayPal Przelewy24 Shop Pay Twint Union Pay USDC Visa

Deine Zahlungsinformationen werden sicher verarbeitet. Wir speichern keine Kreditkartendaten und haben auch keinen Zugang zu deinen Kreditkartendaten.

Quantity Discount Promotion
🎯 BULK DISCOUNT: Buy More, Save More!
Buy 2 Items
5% OFF
Buy 4 Items
10% OFF
Buy 6 Items
15% OFF
Expert

DIY Expert Support

Get fitment advice & recommendations

Mon-Fri, 8:30AM-8PM
24-Hour Fast Ship
🚚
Arrives in 3-14 days
🌍
Global Reach
↩️
30-Day Returns
🌱 1 tree planted with every purchase

Beschreibung

PVC 45° Elbow Pressure Fittings — Reliable Directional Change for Water Pipe Systems

When a plumbing run needs to change direction without the sharp restriction of a 90° bend, DIYers and trade professionals alike reach for a 45-degree elbow. These PVC 45° elbow pressure fittings are designed for solvent-weld (adhesive) assembly on schedule-rated water pipe systems, giving you a smooth, leak-resistant joint that holds up under sustained pressure in both residential and light commercial applications.

Each fitting is manufactured from rigid PVC (polyvinyl chloride) with a smooth internal bore and a solvent-weld socket on both ends. Available in inner-diameter sizes from 20mm (~¾ in) through 125mm (~5 in), with colour options in White, Blue, and Gray to suit different system conventions or aesthetic preferences. Wall thickness and pressure rating vary by size — see variant options for confirmed specifications.

Typical use cases include irrigation lateral lines requiring a gentle directional offset, domestic cold-water supply runs routed around structural obstacles, and drainage pre-slope sections where a 45° angle is specified by code. The solvent-weld connection method makes these fittings a go-to choice for PVC pipe elbow 45 degree irrigation and PVC pressure fitting solvent weld cold water supply projects.

🔗 Compatibility: Designed for solvent-weld (adhesive) assembly with Schedule 40 / Class B rigid PVC pressure pipe. Match the fitting ID to your pipe's outer diameter. Not suitable for CPVC, ABS, or threaded connections.

✅ Key Features of These PVC 45° Elbow Pressure Fittings

  • 📐Wide Size Range: Inner diameters from 20mm to 125mm (approximately ¾ in to 5 in) cover the most common residential and light commercial pipe sizes in a single product family.
  • 🎨Three Colour Options: White, Blue, and Gray variants allow you to match existing system colour-coding conventions or blend with visible pipework aesthetics.
  • 🔩Solvent-Weld Socket Ends: Both ends feature a precision-machined socket bore sized for standard PVC solvent cement, producing a chemically fused, permanent joint with no mechanical fasteners required.
  • 💧Smooth Internal Bore: The 45° sweep geometry minimises turbulence and pressure drop compared to a 90° elbow, maintaining flow efficiency across the directional change.
  • 🛡️Corrosion and Chemical Resistance: Rigid PVC is inherently resistant to rust, scale, and a broad range of water treatment chemicals, making these fittings suitable for chlorinated mains water and standard irrigation solutions.
  • 📦Flexible Pack Quantities: Available in 1, 2, 4, 10, and 15-piece packs so you can order exactly what a single repair needs or stock up for a larger installation run.

📐 Technical Specifications — PVC 45° Elbow Pressure Fittings

Material Rigid PVC (Polyvinyl Chloride)
Fitting Type 45° Elbow, Solvent-Weld (Adhesive) Socket
Inner Diameter (ID) Range 20mm – 125mm (approx. ¾ in – 5 in)
Available Sizes (this listing) 20mm, 25mm, 32mm, 40mm
Colour / Finish White, Blue, Gray
Connection Method Solvent Cement (Adhesive) Weld — both ends
Pressure Rating See variant options
Wall Thickness See variant options
Compatible Pipe Standard Schedule 40 / Class B rigid PVC pressure pipe
Temperature Range Typically 0°C – 60°C (32°F – 140°F) for cold-water service
Pack Quantities Available 1, 2, 4, 10, 15 Pcs

❓ Frequently Asked Questions

How do I choose the right size PVC 45° elbow for my pipe?

Match the fitting's inner diameter (ID) to your pipe's outer diameter (OD) — for Schedule 40 PVC pipe, the nominal pipe size and the fitting socket ID are designed to be compatible. For example, a 20mm fitting suits 20mm OD pipe. If you are unsure, measure the outside of your pipe with calipers and select the closest matching fitting ID from the variant options.

Can these fittings handle mains water pressure?

These are pressure-rated fittings designed for solvent-weld water pipe systems. Exact pressure ratings vary by size — larger diameters typically carry a lower maximum working pressure. Check the variant-specific pressure rating or contact us to confirm suitability for your system's operating pressure before installation.

Are these fittings suitable for hot water lines?

No. Rigid PVC pressure fittings are rated for cold-water service only, typically up to 60°C (140°F) under reduced pressure. For hot water supply lines, CPVC or copper fittings are the appropriate choice. These PVC elbows are intended for cold-water supply, irrigation, and drainage applications.

What adhesive should I use to join these fittings?

Use a PVC solvent cement (solvent weld adhesive) rated for pressure pipe applications. Apply a PVC primer to both the pipe end and the fitting socket, then apply solvent cement to both surfaces and push the pipe firmly into the socket with a slight twist. Allow the joint to cure per the cement manufacturer's instructions before pressurising the system.

Will these fittings corrode or degrade in outdoor irrigation systems?

Rigid PVC is inherently corrosion-resistant and unaffected by standard irrigation water, fertiliser solutions, and chlorinated mains water. However, prolonged direct UV exposure can cause surface chalking over time. For above-ground outdoor runs, painting the fittings with a water-based exterior paint or wrapping with UV-protective tape is recommended to extend service life.

Why choose a 45° elbow instead of a 90° elbow?

A 45° elbow creates a gentler directional change, which reduces turbulence, pressure drop, and flow restriction compared to a 90° bend. This makes it the preferred choice for longer pipe runs where maintaining flow rate matters, for gravity-fed drainage slopes, and for situations where two 45° elbows are used in sequence to achieve a 90° offset with a longer sweep radius.

Can I use these fittings with ABS or CPVC pipe?

No. These fittings are designed exclusively for rigid PVC pipe using PVC solvent cement. ABS and CPVC pipes require their own compatible fittings and adhesives. Using mismatched materials can result in joint failure. Always confirm your pipe material before selecting fittings.

🛒 Select your size, colour, and pack quantity above, then add to cart.

You may also like

Recently viewed