1. Product core introduction
HomeDIYer presents the DZ47-60 Timer Switch Circuit Breaker for 220V circuits with a current range of 1A - 60A.This unique DZ47 circuit breaker combines timing and disconnecting functions to provide overcurrent protection for appliances as well as timer control for a wide range of scenarios, bringing safety and convenience to your home or office electrical system.
2. The main characteristics of the product
Multi-function in one: integrating timing control and circuit protection functions, reducing additional wiring and equipment installation space. Users can set a specific time period according to the need, so that the connected electrical appliances will be automatically powered on or off within the preset time to achieve intelligent control, and at the same time, it has the overcurrent protection function of traditional circuit breakers, which effectively prevents damage to the equipment due to overloads, short-circuits, and other electrical faults and provides all-around protection and management of the electrical appliances and equipment, and enhances the safety and convenience of electricity consumption.
Wide Current Adaptation: The current specification is widely covered from 1A to 60A, which can meet the needs of different power appliances. Whether it is low-power small lighting fixtures, chargers, or high-power air conditioners, electric water heaters, electric heaters, etc., all can find the appropriate current specifications to ensure that the circuit breaker operates stably within the range of normal operating current, accurately protects various types of electrical equipment, avoids protection failures or malfunctions due to mismatch of currents, optimises the protection configuration of the electrical system, and improves the overall safety and reliability.
Precise timing control: Adopting advanced timing technology, it can realise precise time setting, and the smallest timing unit can reach the level of minutes, so that users can flexibly set the switching time of electrical appliances according to the actual demand of electricity consumption in daily life or work. For example, setting the water heater to automatically heat up at night during the low tariff period, or allowing the lighting to automatically switch on and off at specific time periods can not only satisfy the demand for use, but also save energy, improve the efficiency of electricity consumption, and bring the user a smarter and more convenient experience of electricity consumption.
Reliable quality assurance: Inheriting the excellent quality of DZ47 series circuit breakers, the shell is made of high-quality flame-retardant and insulating materials with good heat resistance, corrosion resistance and mechanical strength, which can effectively resist collision, scraping, and a certain degree of high temperature and humidity in daily use. The internal contacts and release mechanism are carefully designed and rigorously tested, with sensitive and reliable action, ensuring stable performance during long-term frequent use, reducing maintenance costs and replacement frequency, and providing a solid guarantee for long-term stable electrical protection and timing control.
3. Product use scene
Electricity for family life: In the family environment, it can be used to control various electrical devices, such as electric water heaters, air conditioners, electric heaters, lighting fixtures, fish tank oxygenation pumps, pet feeders and so on. By setting the timer switch function, you can make the electric water heater automatically heat up the hot water in the morning before washing, the air conditioner turn on the cooling or heating in advance before coming home from work, and the lighting fixtures automatically light up after dark, avoiding unnecessary energy consumption and also increasing the convenience and comfort of life; for the equipment such as the fish tank oxygen pump and the pet feeder, the timer switch function ensures that the living environment of the pets is stable and maintained, even if the owner is not at home. Maintenance, even if the owner is not at home can be in accordance with the preset time normal operation, to enhance the intelligent level and quality of family life.
Office application: It is applicable to the lighting system, water dispenser, printer, copier and other equipments in the office. In the office area, by setting the timer switch of lighting fixtures, the lights can be automatically controlled to turn on and off according to the working time, saving energy; the water dispenser can be automatically energised and heated during working hours, and then automatically powered off after work, avoiding the waste of energy and potential safety hazards caused by repeated heating; the power-off of printers, photocopiers and other equipments during non-working hours not only saves electricity, but also prolongs the service life of the equipments and reduces the occurrence of faults caused by prolonged standby time. The power off of printers and photocopiers during non-working hours not only saves electricity, but also extends the service life of the equipment and reduces the chance of failure due to long standby time, which provides an efficient, energy-saving and safe power management solution for the office.
Commercial shop operation: In commercial shops, it can be used to control signboard lights, window lighting, air conditioners, electric fans and other equipment. Businessmen can set the timer switch of signboard lights and window lighting according to the business hours of the shop to attract customers and save electricity expenses; in summer or winter, by controlling the running time of air-conditioners and electric fans at regular intervals, it can provide customers with a comfortable shopping environment and at the same time reduce the operating costs to improve the efficiency and competitiveness of commercial operations, providing a convenient and energy-saving solution for the daily operation of commercial shops.
4. Product use instructions
Install the DZ47-60 Timing Switch Circuit Breaker on the guide rail of the distribution box and make sure it is firmly installed without looseness. According to the wiring plan of the electrical system, connect the fire wire to the fire wire input of the circuit breaker (usually labelled with ‘L’), the zero wire to the zero wire input (labelled with ‘N’), and the load wire to the output terminal, paying attention to the correctness and firmness of the wiring, avoiding misconnection line or false connection. After the wiring is completed, use a screwdriver to tighten the screws on the terminals to ensure that the wires are in close contact with the terminals and to prevent heat, fire or malfunction due to poor contact.
Timing function setting:
According to the actual demand, set the time parameters through the timing setting button or knob on the circuit breaker. Generally, the hours and minutes of timed-on, the hours and minutes of timed-off, and whether or not cyclic timing is required can be set sequentially in accordance with the instruction manual or operation guide of the equipment. During the setting process, attention should be paid to the accuracy and reasonableness of the operation to ensure that the timing function can run according to the expected time plan. After the setting is completed, you can confirm whether the timing setting is successful by observing the display (if any) or indicator on the circuit breaker.
Commissioning and Testing:
After completing the installation, wiring and timing setting, close the circuit breaker to check whether it can work normally. First of all, check whether the circuit is normally energised, use electrical equipment to test whether the overcurrent protection function is normal, by gradually increasing the load current until it exceeds the rated current of the circuit breaker, and observe whether the circuit breaker is able to trip and cut off the power supply in the specified time; then, test the timing switch function, and observe whether the electrical equipment is automatically switched on and off at the predetermined time in accordance with the time schedule set, if any problem is found, it should be promptly check the wiring, timing settings and the internal structure of the circuit breaker, and make corresponding adjustments and repairs.